Manhole label to include a editable description

It would be useful to be able to add a description to manhole labels to provide descriptions such as 'existing manhole to be retained', 'recessed cover', etc.
Cham Ariyaratne 1 day ago in LiveDesign 0

Manhole orientation to match architecture

It would be really useful to be able to align rectangular manholes to match the architectural constraints of a building such as a orientation of a corridor/wall. Currently LiveDesign can only show manholes with the orientation centred and perpendi...
Cham Ariyaratne 6 days ago in LiveDesign 0

negative cover depths visual warning

Is there a way that Flow could highlight where there is a negative cover depth? As it’s not too bad on a small network to search through all the links, but as the network gets larger it becomes harder to do. It’s only just that the red/orange/gree...
Guest 5 months ago in Flow 0 📋Registered

Embodied Carbon Calculation

Embedded carbon calculation per M of PIpe and surround and carbon report output
Guest over 1 year ago in Flow 1 👷🏽‍♀️Promoted

Time Area Diagram in m2 for Green Roof Runoff Method

Change the units for the area column in the time area diagram to m2 (or have the ability for user to change the units between m2 and ha). When using time area diagram, as per the Green Roof Runoff Method (link below), it results in areas of 0.001 ...
Ryan Saunders 7 months ago in Flow 0 📋Registered

Total Impermeable Area on Calcs Printout

The sum of the total impermeable area is not currently printed on the calcs, this could be incorporated with the total Time/Area information (as per a previous suggestion) as MicroDrainage does.
Ian George over 2 years ago in Flow 0 👷🏽‍♀️Promoted

Total Volume of Structure

Finding total volume of a structure would be useful (similar to the volume Static Tool in MicroDrainage).At present the only way to do it is look at the storage tab and hover over a depth in the storage structure section and it shows the depth and...
Ian George over 2 years ago in Flow 0 👷🏽‍♀️Promoted

Minimum Pipe Length

The mimimum pipe length in Flow is currently set to 1m. Where modelling junctions and connections there may be less than 1m between the junctions. Please revise the minimum length to around 300-500mm.
Ian George over 2 years ago in Flow 1 👷🏽‍♀️Promoted

To be able to show pipe crossings when plotting long sections.

When plotting long sections, it would be useful to be able to show the crossings from other drainage networks. The crossing are shown on the long sections viewer in flow but not when you plot them.
Guest over 1 year ago in Flow 0 👷🏽‍♀️Promoted

When changing gradients on pipe, automatically changing the downstream pipe to level soffit rather than having to change invert level manually.

No description provided
Tom Fox over 2 years ago in Flow 0 👷🏽‍♀️Promoted