COBie information for drainage systems

Clients are requesting we provide COBie information for drainage systems - it would be useful to have the ability to embed COBie data into the drainage model and export it for others to use. This is likely to be a more suitable feature in Flow but...
Amy Norman 12 days ago in Flow 0

To be able to show pipe crossings when plotting long sections.

When plotting long sections, it would be useful to be able to show the crossings from other drainage networks. The crossing are shown on the long sections viewer in flow but not when you plot them.
Guest 4 months ago in Flow 0

Infiltration Half Drain time calculations

We have recently been challenged by Wiltshire LLFA regarding half drain times. As I understand it, Flow calculates the half drain time to CIRIA 156 which gives a significantly longer half drain time than the BRE365 method that Micro Drainage uses....
Ben Stoodley about 2 months ago in Flow 0

Infiltration volume

Add a column called ‘Infiltration Volume’ to the simulation results table which indicates the total volume of water infiltrating into the ground at the upstream manhole during the selected storm.
Guest 3 months ago in Flow 0

Pipe Selection/visibility in output

There is often need to hide certain pipes from the final output. Either they are dummy pipes that have no relation to the final layout or they are areas outside the specific design network that do not need to be included in the report. Microdraina...
Guest 7 months ago in Flow 0

Time to half empty Calculations

I have a request regards time to half empty of infiltration systems. Irrespective of what I set in the preference page (whether time to half empty by volume or by storm) I just get time to half empty of the structure. That isn’t very useful inform...
Steve Doughty 5 months ago in Flow 0

Minimum Pipe Length

The mimimum pipe length in Flow is currently set to 1m. Where modelling junctions and connections there may be less than 1m between the junctions. Please revise the minimum length to around 300-500mm.
Ian George over 1 year ago in Flow 1

Quick Storage Calculations For Soakaways Without The Use Of The Base

When looking at the preliminary quick storage calculations used for preliminary designs/drainage strategies, the quick storage tool is excellent up until the point you want to design soakaways as there is no option to get a quick storage calculati...
Guest 4 months ago in Flow 0

When changing gradients on pipe, automatically changing the downstream pipe to level soffit rather than having to change invert level manually.

No description provided
Tom Fox over 1 year ago in Flow 0

Flow through permeable paving

On sites where there's a shallow outfall it would be useful to be ablet to model permeable paving without the need to have an under drain, in doing so it would be similar to flow through ponds
Guest 2 months ago in Flow 0