Skip to Main Content
Design Ideas Portal
ADD A NEW IDEA

All ideas

Showing 123 of 123

Chainage, pipe bedding and cover grade information in long section exports

Add chainage, pipe bedding and node cover grade information as options for long section outputs. These are standard requirements for a lot of water authorities so would prevent manual changes being required to allow these outputs to be included.
Guest 2 days ago in Flow 0 📋Registered

BIM Collaboration

Improved modelling, including building drainage so designs can be modelled to base of internal stacks within buildings to allow for greater collaboration between other design disciplines for general clash detection. Typically, Architects, Structur...
Guest 10 days ago in Flow 0 📋Registered

Embodied Carbon Calculation

Embedded carbon calculation per M of PIpe and surround and carbon report output
Guest 11 months ago in Flow 1 👷🏽‍♀️Promoted

Add Loading classification to Manhole schedule

Add a column for manhole cover loading classification on manhole schedule. Required for S104 and construction plans
Guest 2 months ago in Flow 0 👷🏽‍♀️Promoted

Cumulative area discounts flow through structures and network before

The cumulative area calculation discounts everything before a flow through structure and the nodes attached to the structure. LLFA's are now requesting calc files due to the print out also reading your incorrect pathing of calculations. Theirs no ...
Guest 2 months ago in Flow 0 👷🏽‍♀️Promoted

Manhole Schedule Degree Reference

We’ve noticed a significant increase in the use of precast manholes across nearly every development we’re involved in. The companies supplying these typically issue drawings where each incoming pipe is referenced by its angle relative to the outgo...
Guest 24 days ago in Flow 0 📋Registered

Highlight if the Colebrook-White or the Manning's equations is being used by highlighting (or greying out) the "ks (mm)" or "n" in the link details.

It seems that if a pipe has a swale upstream then the pipe uses the Manning's equations to compute flows etc, but if it has nothing upstream or a pipe upsteam then it uses the Colebrook-White equations. This means that on the same storm water syst...
James Berry about 2 months ago in Flow 0 📋Registered

To be able to show pipe crossings when plotting long sections.

When plotting long sections, it would be useful to be able to show the crossings from other drainage networks. The crossing are shown on the long sections viewer in flow but not when you plot them.
Guest 9 months ago in Flow 0 👷🏽‍♀️Promoted

Customise the section box appearance for long sections

Being able to adjust the depth of the rows in the section box will speed up the process of producing the long section drawing. Alterations to the table are typically also required in order to be able to read all the information. Setting the text m...
Guest 25 days ago in SmartTools 0 📋Registered

Time to half empty Calculations

I have a request regards time to half empty of infiltration systems. Irrespective of what I set in the preference page (whether time to half empty by volume or by storm) I just get time to half empty of the structure. That isn’t very useful inform...
Steve Doughty 10 months ago in Flow 0 👷🏽‍♀️Promoted