Flow through structure Mass balance Issue

Always having mass balance issues when utilising flow through structure. It could be something from adding orifice to inlets same size as pipe, lifting/dropping structure slightly increasing/decreasing length of structure, that sorts the issue. Th...
Guest 3 months ago in Flow 0 📋Registered

General user interface improvements

Having used Flow now for the last 6 months we feel there are plenty of user interface improvements than can be made. Add the link references in the results? When a link is selected, can the corresponding link on the section be highlight with a col...
Ben Stoodley over 1 year ago in Flow 0 👷🏽‍♀️Promoted

Change Porosity display

In the new update when you add the porosity it displays that porosity but it is quite an eye sore and would be beneficial to be able to remove or tone it down a bit.
Guest 4 months ago in Flow 0 📋Registered

Ability to hide junctions/RWPs/etc. from the model output manhole schedule. Same with links.

No description provided
Tom Fox about 2 years ago in Flow 0 👷🏽‍♀️Promoted

sort tables

Either add facility to sort table entries numerically by node or link number - or amend software so that the tabulated data automatically displays in numerical order even after a model has been altered by adding or renumbering nodes. This would he...
Guest over 1 year ago in Flow 0 👷🏽‍♀️Promoted

Separating Flow Design Reports - Ability to split large flow networks into phased design reports.

There is a requirement to be able to produce design reports for separate sections of a larger Flow network when working on multi-phase developments.
Craig McNaughton 7 months ago in Flow 0 👷🏽‍♀️Promoted

Dark mode

I understand that it might be a stretch, but it would be great if there was a possibility to switch to dark mode in Flow.
Lukasz Maslinski over 1 year ago in Flow 0 👷🏽‍♀️Promoted

Add a 'lock Node/Catchment positions' button to the Sketch window.

This is a very serious issue, if you accidently move an area, SmartTools will then double count that area next time you import it into Flow
Tom Fox about 2 years ago in Flow 0 👷🏽‍♀️Promoted

Provide technical guidance an the use of ReFH2 in Flow

There is an absence of guidance on the use of ReFH2 data in Flow. I understand from discussions with the Help Desk that they don't have access to the software. In the absence of reasonable guidance the ReFH2 features are worthless.
karl Pitman 4 months ago in Flow 0 📋Registered

Chainage, pipe bedding and cover grade information in long section exports

Add chainage, pipe bedding and node cover grade information as options for long section outputs. These are standard requirements for a lot of water authorities so would prevent manual changes being required to allow these outputs to be included.
Guest 4 months ago in Flow 0 📋Registered