Ability to generate cross-section profiles within Flow, Live Design and SmartTools.

No description provided
Tom Fox almost 2 years ago in Flow 0 👷🏽‍♀️Promoted

Cache input hydrographs, unless parameters changed

It takes a long time for Causeway to open and run RefH2. When designing a network with input hydrographs, it becomes a slow process to re-run the model when making changes to the drainage infrastructure. It would make sense to save the generated i...
Henry Kelly 11 months ago in Flow 0 👷🏽‍♀️Promoted

Specific Statement of Storage in tank or pond

I don't believe it is possible to simply display the storage amount in printed results (Design Report) as a separate entity. It does of course show up within the results list for the various storms, however, this is not very clear and of course is...
Guest 11 months ago in Flow 0 👷🏽‍♀️Promoted

Radial Infiltration Rate for Deep Bore Soakaway

The software asks for infiltration rate as m/hr which is based on BRE365 Infiltration testing in trial pits. Trial pits are not feasible for deep infiltration and as such the radial infiltration rate, the one we get from borehole testing, should b...
Emilie Leclerc almost 2 years ago in Flow 0 👷🏽‍♀️Promoted

Optimisation tool for storage structures

A wizard for reducing down one or more storage structures to the optimum required size. Something like this: Select all storage features of interest. Enter key design criteria (e.g. max depth, porosity, design storm of interest etc.) Run an optimi...
Henry Kelly almost 2 years ago in Flow 0 👷🏽‍♀️Promoted

Outfall Invert Level in the Centre of Storage.

We are trying to add storage off of a manhole, however don't want the IL as per the manhole or the base of storage. We have designed the soakaway 10m x 20m with a depth of 1m. We want the IL to be different to the manhole IL and have added the soa...
Guest 12 months ago in Flow 0 👷🏽‍♀️Promoted

Auto pipe sizing per number of dwellings contributing

We need to upsize wastewater pipes from 150mm dia. to 225mm dia. as soon as the total number of dwellings contributing to that pipe exceeds 20. Could this be added to the Auto-design parameters?
Ian Reilly almost 2 years ago in Flow 0 👷🏽‍♀️Promoted

Slope in percentage

Just a preference option to dispaly slopes in percentage rather than in 1:X only in Flow.
Lukasz Maslinski 12 months ago in Flow 0 👷🏽‍♀️Promoted

Window size when moving Flow between multiple screens

Why does the window size of Flow decrease so much if it is moved from one screen to another when using multiple screens? Somewhat annoying to have to re-size it in the 2nd screen
Ian Woolgar almost 2 years ago in Flow 0 👷🏽‍♀️Promoted

pre-development discharge rates/ volumes

When calculating the pre-development discharge rates you get the Qbar and the Qmed for the requested return periods. For discussions with utility providers would be useful to obtain it for storm durations like the 15minutes and 30 minutes storm.
Levente Incze almost 2 years ago in Flow 0 👷🏽‍♀️Promoted