Skip to Main Content
Design Ideas Portal
ADD A NEW IDEA

All ideas

Showing 143 of 143

Yellow box marking for roundabout circulatorys

Be able to create a yellow box marking for roundabout circulatorys. Currently yellow box markings in Line only allow for 4 vertices and are unable to be curved.
Guest 2 months ago in Line 0

Sign 2501 parking place with distance to the informatory menu

An option to design a traffic sign to diag. 2501 (parking place sign with a distance). Currently there is no option to do this without manually creating it.
Guest 2 months ago in Sign 0

PCD Signs to be added to the Informatory menu

An option to quickly design Pollution Control Device signs as per DMRB CG 501 Design of Highway Drainage Systems
Guest 2 months ago in Sign 0

Able to export to IFC directly from Flow

It would be useful for engineers detailing and coordination to export directly from flow to IFC
Guest 3 months ago in Flow 0 📋Registered

Remove Requirement for Infiltration coefficient for porous paving

If designing a lined porous paving system, you are unable to have it non-attenuating. This requirement should be removed to design it to discharge elsewhere
Guest 3 months ago in Flow 0 📋Registered

Ability to renumber and reorder design locked nodes and pipes.

No description provided
Tom Fox about 2 years ago in Flow 0 👷🏽‍♀️Promoted

Highlight if the Colebrook-White or the Manning's equations is being used by highlighting (or greying out) the "ks (mm)" or "n" in the link details.

It seems that if a pipe has a swale upstream then the pipe uses the Manning's equations to compute flows etc, but if it has nothing upstream or a pipe upsteam then it uses the Colebrook-White equations. This means that on the same storm water syst...
James Berry 6 months ago in Flow 0 📋Registered

placing retaining walls/stairs

some sites we are working on have had some significant level differences, which has led to the need for retaining walls. At present Live Design tries to grade the surface between these level differences. Please can you add a feature where a retain...
Guest over 2 years ago in LiveDesign 0 Planned

Flow through structure Mass balance Issue

Always having mass balance issues when utilising flow through structure. It could be something from adding orifice to inlets same size as pipe, lifting/dropping structure slightly increasing/decreasing length of structure, that sorts the issue. Th...
Guest 3 months ago in Flow 0 📋Registered

Quick Storage Calculations For Soakaways Without The Use Of The Base

When looking at the preliminary quick storage calculations used for preliminary designs/drainage strategies, the quick storage tool is excellent up until the point you want to design soakaways as there is no option to get a quick storage calculati...
Guest about 1 year ago in Flow 0 👷🏽‍♀️Promoted