Ability to add design parameters

It would be helpful to have following parameters, including the ability to define them globally as well as locally (for node or links) Maximum gradient Minimum Gradient Maximum drop Allow Drop (locally) Maximum cover
Guest about 1 year ago in Flow 0 👷🏽‍♀️Promoted

Auto pipe sizing per number of dwellings contributing

We need to upsize wastewater pipes from 150mm dia. to 225mm dia. as soon as the total number of dwellings contributing to that pipe exceeds 20. Could this be added to the Auto-design parameters?
Ian Reilly about 2 years ago in Flow 0 👷🏽‍♀️Promoted

Window size when moving Flow between multiple screens

Why does the window size of Flow decrease so much if it is moved from one screen to another when using multiple screens? Somewhat annoying to have to re-size it in the 2nd screen
Ian Woolgar over 2 years ago in Flow 0 👷🏽‍♀️Promoted

pre-development discharge rates/ volumes

When calculating the pre-development discharge rates you get the Qbar and the Qmed for the requested return periods. For discussions with utility providers would be useful to obtain it for storm durations like the 15minutes and 30 minutes storm.
Levente Incze over 2 years ago in Flow 0 👷🏽‍♀️Promoted

Cache input hydrographs, unless parameters changed

It takes a long time for Causeway to open and run RefH2. When designing a network with input hydrographs, it becomes a slow process to re-run the model when making changes to the drainage infrastructure. It would make sense to save the generated i...
Henry Kelly about 1 year ago in Flow 0 👷🏽‍♀️Promoted

Specific Statement of Storage in tank or pond

I don't believe it is possible to simply display the storage amount in printed results (Design Report) as a separate entity. It does of course show up within the results list for the various storms, however, this is not very clear and of course is...
Guest about 1 year ago in Flow 0 👷🏽‍♀️Promoted

Outfall Invert Level in the Centre of Storage.

We are trying to add storage off of a manhole, however don't want the IL as per the manhole or the base of storage. We have designed the soakaway 10m x 20m with a depth of 1m. We want the IL to be different to the manhole IL and have added the soa...
Guest about 1 year ago in Flow 0 👷🏽‍♀️Promoted

Slope in percentage

Just a preference option to dispaly slopes in percentage rather than in 1:X only in Flow.
Lukasz Maslinski over 1 year ago in Flow 0 👷🏽‍♀️Promoted

.pfd File Locking - 'Read Only' Status

There doesnt seem to be any 'locking' of PFD files when they're opened. Currently individuals, or multiple users, can open the same file and overright it. Clearly thats less than ideal! It also happens with SmartTools, if you export out of SmartTo...
Ian George over 1 year ago in Flow 0 👷🏽‍♀️Promoted

Export Flow Design to native .INP for use in other programmes